Dayton
Dayton 1A580 Brass Solenoid Valve Trap 1 1/4 in Normally Closed 250 psi 16 Cv
Brass solenoid valve body, normally closed, 1 1/4 in pipe, 16 Cv, 250 psi max pressure, 180 °F fluid temperature
- TypeDrain Components
- Brass body resists corrosion for long service life
- Normally closed design stops flow when power is lost
- 16 Cv rating handles high-volume liquid or gas flow
- Operates up to 250 psi for demanding pressure applications
- Suitable for indoor and outdoor installation environments
Brass Solenoid Valve Trap 1 1/4 in
The Dayton 1A580 is a brass solenoid valve trap designed for drain and trap applications. It features a 1 1/4 inch nominal pipe size with a 2-way, normally closed configuration and a 16 Cv flow coefficient. The valve body is rated for a maximum fluid temperature of 180 Degrees F.
Suits indoor or outdoor drain lines needing 250
This valve suits plumbing systems requiring a normally closed solenoid for air, inert gas, or water service up to 250 psi differential pressure. It is not for buyers who need an integrated coil or a lower minimum operating pressure differential than 5 psi. The Proposition 65 warning applies for California installations.
Verify pipe size, pressure range
Before ordering, confirm your system uses 1 1/4 inch piping and operates within the 5 to 250 psi differential range. Ensure the fluid temperature does not exceed 180 Degrees F. Check that your separate coil matches the valve body specifications for voltage and environmental rating.
Highlights
- Brass body resists corrosion for long service life
- Normally closed design stops flow when power is lost
- 16 Cv rating handles high-volume liquid or gas flow
- Operates up to 250 psi for demanding pressure applications
- Suitable for indoor and outdoor installation environments
Specifications
| Type | Drain Components |
|---|---|
| Brand | Dayton |
| Model | 1A580 |
Questions about this item
What size pipe and coil voltage do I need to match this 1 1/4 in normally-closed brass body?
The valve body has a 1 1/4 in nominal pipe size and 1 1/4 in orifice; it is sold without a coil, so you must supply a compatible 2-way solenoid coil separately.
Will the 5 psi minimum pressure differential work with my existing low-pressure air line?
The valve requires at least 5 psi differential to open and handles up to 250 psi for air, inert gas or water, so your line must stay above 5 psi during operation.
How can I verify the 16 Cv flow rating is achieved after installation?
With the correct coil energised, measure flow at your operating pressure; a 16 Cv rating means 16 US gallons per minute of water at 1 psi pressure drop across the 1 1/4 in orifice.