CENTURY
CENTURY D1076 PSC 3/4 HP 1075 RPM 208-230V 48Y OAO HVAC Control
Direct-drive PSC blower motor delivering 3/4 HP at 1075 RPM on 208-230 V with three-speed operation and 26 in leads
- 3/4 HP motor delivers strong airflow for HVAC systems
- Three-speed PSC design lets you match output to demand
- 208-230 V AC rating fits common residential and light-commercial wiring
- Auto thermal protection guards against overheating during extended runs
- 26 in leads and ring mounting simplify direct-drive blower replacement
Direct-drive blower motor for HVAC systems
This CENTURY D1076 permanent split capacitor motor delivers 3/4 HP at 1075 RPM for direct-drive blower applications in heating and cooling equipment. It operates on 208-230 V AC single-phase power at 60 Hz and draws 5.1 A at full load.
Ring-mount design with auto thermal protection
The 48-frame motor uses a ring mounting type and a single shaft with clockwise or counter-clockwise rotation. Leads measure 26 in for connection inside the unit. Auto thermal protection resets automatically after an over-temperature event. The open air-over enclosure requires airflow from the blower wheel for cooling.
Voltage and ambient limits
Operation is approved down to 208 V but not at 200 V. Maximum ambient temperature is 40 °C. The motor carries a 1.0 service factor and Class B insulation, so it cannot be run continuously above nameplate load or in higher-temperature environments.
Highlights
- 3/4 HP motor delivers strong airflow for HVAC systems
- Three-speed PSC design lets you match output to demand
- 208-230 V AC rating fits common residential and light-commercial wiring
- Auto thermal protection guards against overheating during extended runs
- 26 in leads and ring mounting simplify direct-drive blower replacement
Specifications
| Brand | CENTURY |
|---|
Questions about this item
How can I verify the motor is running correctly after installation?
Confirm the motor reaches 1075 RPM nameplate speed, draws approximately 5.1 A at full load, and the auto thermal protection does not trip during operation.
What components are included and what must be sourced separately?
The motor ships with a 26-inch lead length for wiring; a compatible run capacitor, mounting ring hardware, and any required conduit or connectors are not included.
Which voltage and frame version should I select for a 208 V horizontal blower application?
Choose the 208-230 V, 48 frame model; it is rated usable at 208 V but not at 200 V, and the horizontal mounting position matches your blower orientation.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.