Carol
Carol C6355A.41.10 Comm Cable 20/5 1000 Ft
Unshielded 20 AWG 5-conductor PVC communication cable in a 1,000 ft pulling pack for commercial audio and control systems
- TypeWire & Cable
- Color MappingGray
- 1000 ft pull length simplifies large installs
- Unshielded 5-conductor design suits basic comms
- 20 AWG stranded conductors stay flexible in runs
- Gray PVC jacket meets CM fire rating
- Rated 300 V for low-voltage control circuits
Carol C6355A.41.10 Communication Cable
This Carol C6355A.41.10 communication cable provides 1000 ft of unshielded wiring for commercial installations. It features five stranded conductors at 20 AWG with gray PVC insulation and jacket. The cable carries a CM fire rating per NEC Article 800 and supports a maximum voltage of 300 V for communications, audio, and control systems.
Thermals noise and power draw in normal use
As a passive copper cable, the product generates no heat, noise, or power draw during operation. The PVC jacket and insulation are rated for standard commercial environmental conditions. Electrical performance is limited to the 300 V maximum rating and the inherent resistance of the 20 AWG stranded conductors over the installed length.
Upgrade from single pair or shielded runs
This five-conductor cable replaces single-pair or lower-count wiring when multiple circuits must share a single pull. It is not suited for buyers who require electromagnetic shielding, plenum fire ratings, or conductor gauges larger than 20 AWG for lower voltage drop over long distances.
Highlights
- 1000 ft pull length simplifies large installs
- Unshielded 5-conductor design suits basic comms
- 20 AWG stranded conductors stay flexible in runs
- Gray PVC jacket meets CM fire rating
- Rated 300 V for low-voltage control circuits
Specifications
| Type | Wire & Cable |
|---|---|
| Brand | CAROL |
| Color Mapping | Gray |
Questions about this item
How do I pull this 1000 ft unshielded communication cable through conduit without damaging the conductors?
Feed the cable from the pulling pack so the jacket unwinds straight; keep bend radius generous because the 0.3 in outside diameter with stranded 20 AWG conductors can kink if forced around tight corners.
Will the PVC jacket or insulation need replacement after long-term indoor runs?
The PVC jacket and insulation are rated for commercial fire applications under NEC 800 CM; they do not require scheduled replacement unless physical damage or excessive heat above the 300 V rating occurs.
What is the first performance limit I will hit on a continuous 300 V control circuit?
The 20 AWG stranded conductors set the practical limit — voltage drop over distance and the 300 V maximum rating will constrain circuit length before the PVC jacket or CM fire rating becomes a factor.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Wilson Antennas 305-480 2 ft Silver Load FGT Fiberglass Whip Black antenna
Galtronics 02130269-04935U Indoor Omni Antenna 617-6000MHz 4.3-10 Female
- Antenna
Galtronics 02121269-04935U broadband ceiling mount omni antenna 698-6000MHz
- Antenna mount