Caddy K16 Conduit Hanger 3/4 in 1 in Steel Zinc
Secures 1/2 in, 3/4 in and 1 in EMT, ENT or RMC conduit to 1/8 in to 1/2 in flanges with a spring-pressure clip rated for 15 lb
- Supports 15 lb load capacity for secure mounting
- Fits 1/2 in to 1 in conduit trade sizes
- Spring-pressure mounting requires no tools for installation
- cULus listed and ITB rated for code compliance
- Corrosion-resistant coated steel withstands harsh environments
Conduit hanger for EMT and pipe
The Caddy K16 conduit hanger secures EMT conduit and pipe sizes of 3/4 inch and 1 inch using spring-pressure mounting on flanges from 1/8 inch to 1/2 inch thick. It accepts compatible conduit trade sizes of 1/2 inch, 3/4 inch, and 1 inch across EMT, ENT, and RMC types. The steel body carries a corrosion-resistant gray coating for durability in indoor and outdoor installations.
No-tools spring-pressure mounting
Installation requires no tools because the spring-pressure design grips the flange and conduit automatically. The hanger also supports IMT and MC/AC cable with a maximum outer diameter of 1.181 inch, and the wire range covers 8 AWG to 9 AWG. A 1/4 inch and 3/16 inch thread size allows additional fastening options when needed.
15 lb load capacity rating
The single specification that decides fit is the 15 lb load capacity, which limits the hanger to lightweight conduit runs and cable bundles. Builders who need to support heavier pipe, multiple parallel runs, or dynamic vibration loads must select a different hanger rated for higher weight. The cULus and ITB listings confirm compliance for the stated capacity only.
Highlights
- Supports 15 lb load capacity for secure mounting
- Fits 1/2 in to 1 in conduit trade sizes
- Spring-pressure mounting requires no tools for installation
- cULus listed and ITB rated for code compliance
- Corrosion-resistant coated steel withstands harsh environments
Specifications
| Brand | NVENT CADDY |
|---|
Questions about this item
How often will the spring-pressure mount need checking on the K16 hanger?
The spring-pressure mount has no moving parts to wear; inspect only if vibration loosens the grip on the conduit.
What load limit is reached first when the K16 hanger carries conduit all day?
The 15 lb load capacity is the first limit reached under sustained use.
Does the K16 hanger generate heat or noise when supporting pipe continuously?
The steel zinc hanger produces no heat or noise; it simply holds the conduit in place.