Bussmann
Bussmann GMD-750-R Glass Fuse 750mA 250V AC 10kA 125V AC 5 pack
Pack of five 20 mm glass time-delay fuses rated 750 mA at 250 V AC with a 10 kA interrupt rating at 125 V AC
- Time-delay protection handles surges without nuisance blows
- 10 kA interrupt rating at 125 V AC clears heavy faults safely
- Glass cylindrical body fits standard 20 mm x 5 mm fuse holders
- CSA Class 1422-01 and UL 248-14 certifications confirm compliance
- Pack of 5 provides ready spares for maintenance
Glass Fuse for Circuit Protection
The Bussmann GMD-750-R is a cylindrical glass fuse rated at 750 mA and 250 V AC with a time-delay characteristic. It suits low-current circuits in automotive, generator or industrial equipment where a 5 mm by 20 mm cartridge fits. Each pack contains five fuses for spares or multiple installations.
Replaces Standard Fast-Acting Cartridges
Choose this time-delay version when the circuit experiences brief inrush currents that would nuisance-trip a fast-acting fuse. The 100 A interrupt rating at 250 V AC and 10 kA at 125 V AC cover typical panel and generator fault levels. It directly crosses to Littelfuse 239 and Mersen GSC series parts.
Verify Holder Compatibility Before Buying
Confirm the fuse block accepts a 5 mm diameter by 20 mm length cylindrical body and a non-rejection base; the HTB series is listed as compatible. Ensure the circuit voltage does not exceed 250 V AC and the required interrupt rating matches the 100 A or 10 kA figures. This fuse is not suited for DC circuits or higher voltage applications.
Highlights
- Time-delay protection handles surges without nuisance blows
- 10 kA interrupt rating at 125 V AC clears heavy faults safely
- Glass cylindrical body fits standard 20 mm x 5 mm fuse holders
- CSA Class 1422-01 and UL 248-14 certifications confirm compliance
- Pack of 5 provides ready spares for maintenance
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
Will the 20 mm length and 5 mm diameter fit a standard 5x20 mm fuse holder?
Yes, the cylindrical glass body measures 20 mm long by 5 mm in diameter, matching the common 5x20 mm footprint used in many fuse blocks and panels.
How do I install these time-delay fuses without damaging the glass body?
Press each fuse straight into the clips of a compatible HTB-series fuse block until the metal end caps seat firmly; avoid twisting or excessive force that can crack the glass.
When should I replace a fuse from this 5-pack after it blows?
Replace it immediately with another 750 mA, 250 V AC time-delay fuse of the same 5x20 mm size to maintain the 100 A interrupt rating at 250 V AC and 10 kA at 125 V AC.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.