Bussmann
Bussmann GMC-80-R Glass Fuse 80mA 250V AC Time-Delay 5 PK
A pack of five 20 mm glass time-delay fuses rated 80 mA at 250 V AC with a 35 A interrupt rating at that voltage
- Time-delay protection handles temporary surges without nuisance trips
- 80 mA rating at 250 V AC suits low-current circuits
- 10 kA interrupt rating at 125 V AC clears high faults safely
- 20 mm × 5 mm glass body fits standard 5×20 mm holders
- Pack of 5 fuses provides ready spares for maintenance
Circuit protection for low-current AC circuits
This pack contains five glass-bodied time-delay fuses rated at 80 mA and 250 V AC. They suit equipment that needs a slow-blow response to tolerate brief inrush currents without nuisance opening. The cylindrical 20 mm by 5 mm form factor fits standard fuse holders used in instrumentation, control panels and small appliances.
Interrupt rating defines safe application
Each fuse will safely interrupt up to 10 kA at 125 V AC or 35 A at 250 V AC. This rating is the single figure that tells you whether the fuse can clear a fault on your supply without rupturing. Circuits with prospective fault currents above these values need a different protection device.
Five-piece pack supports spares and multi-point use
The quantity lets you protect several identical circuits or keep replacements on hand for maintenance. No additional hardware, software or mounting accessories are included in the package.
Highlights
- Time-delay protection handles temporary surges without nuisance trips
- 80 mA rating at 250 V AC suits low-current circuits
- 10 kA interrupt rating at 125 V AC clears high faults safely
- 20 mm × 5 mm glass body fits standard 5×20 mm holders
- Pack of 5 fuses provides ready spares for maintenance
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
What does the 80 mA rating mean when the fuse is installed in a circuit?
The fuse will carry up to 80 mA continuously and open after a time delay if the current exceeds that value, protecting downstream components from sustained overloads.
How do the 10 kA at 125 V AC and 35 A at 250 V AC interrupt ratings limit what the fuse can safely break?
At 125 V AC the fuse can interrupt fault currents up to 10 kA, while at 250 V AC it is rated to break only 35 A, so the voltage of the circuit determines the maximum prospective short-circuit current it can handle.
What physical dimensions and mounting style does the 20 mm by 5 mm cylindrical glass body require?
The fuse fits a standard 5 × 20 mm cylindrical holder or clip; its non-rejection glass body slides in without a keyed block and is compatible with HTB series fuse blocks.