BatteryJack inc. 4 Pack SLA Battery 12V 7.5Ah B-613 SLA1075 standard battery
Four-pack of 12 V 7.5 Ah AGM batteries with T1/T2 terminals for UPS, alarms and emergency lighting
- AGM technology delivers maintenance-free, spill-proof operation
- 12 V 7.5 Ah capacity powers UPS, alarms and solar systems
- Compact 5.94 × 2.56 × 3.66 in case fits tight enclosures
- T1/T2 terminals enable direct drop-in replacement
- Four-pack bundle readies multiple devices for backup duty
Four-pack 12 V AGM batteries for standby power
This four-pack supplies sealed 12 V 7.5 Ah AGM cells built as direct replacements for CyberPower units carrying the B-613 and SLA1075 designations. They serve UPS systems, emergency lighting, security panels and similar float-service installations where maintenance-free operation is required.
Fits standard T1/T2 terminals in existing enclosures
Each cell measures 5.94 by 2.56 by 3.66 inches and uses T1/T2 terminals, allowing drop-in installation without rewiring. The spill-proof, position-free construction removes orientation constraints and frees up mounting options inside cabinets, alarm boxes or portable equipment.
Low-pressure venting limits gas build-up in normal
AGM chemistry and a low-pressure venting system keep gas emission minimal during continuous float charging. The sealed design eliminates electrolyte loss, so the batteries run quietly with no watering or equalisation cycles needed throughout their 4-7 year expected service life.
Highlights
- AGM technology delivers maintenance-free, spill-proof operation
- 12 V 7.5 Ah capacity powers UPS, alarms and solar systems
- Compact 5.94 × 2.56 × 3.66 in case fits tight enclosures
- T1/T2 terminals enable direct drop-in replacement
- Four-pack bundle readies multiple devices for backup duty
Specifications
No published specifications for this item yet.
Questions about this item
What limits runtime when this 7.5Ah 12V AGM pack runs a UPS continuously?
The 7.5Ah capacity at 12V sets the total energy available, so runtime ends when the load draws that charge down to the UPS cutoff voltage.
How much heat or off-gassing appears when the sealed AGM cells operate all day in a cabinet?
Low-pressure venting only activates under abuse; normal float use produces negligible heat and no electrolyte vapour because the cells are recombination-sealed.
Which terminal hardware must I already have to connect the T1/T2 posts on each battery?
You need ring or spade lugs that fit the T1/T2 faston tabs, plus the interconnect cables or bus bars to link the four units in series or parallel.