BatteryJack inc.
BatteryJack inc. 12V 7.5AH 90W SLA Battery B-613 SLA1075 7.5ah AGM
A 12 V 7.5 Ah sealed AGM battery delivering 90 W for UPS and backup systems
- Reliable 12V power for UPS and backup systems
- 5Ah capacity delivers 90W of sustained energy
- Advanced AGM technology ensures maintenance-free operation
- Compact 5.94 x 2.56 x 3.66 dimensions fit standard enclosures
- Direct replacement for multiple OEM part numbers
12 V 7.5 Ah AGM battery for standby power
This 12 V 7.5 Ah sealed lead-acid battery uses AGM construction and delivers 90 W of rated power. It is a direct replacement for B-613 and SLA1075 models as well as common 7 Ah and 8 Ah units. The maintenance-free design suits UPS units, alarm panels and emergency lighting systems.
T1/T2 terminals and compact footprint for drop
Terminals accept both T1 and T2 faston connectors, so the battery slides into existing harnesses without adapters. Dimensions of 5.94 by 2.56 by 3.66 inches match the standard 12120 case size used by Power-Sonic, Yuasa, CSB and other brands. The sealed case prevents acid leaks in any orientation.
Sealed AGM chemistry runs cool with no watering
Absorbed glass mat electrolyte eliminates gassing during normal float charging, so the battery operates silently and stays cool in enclosed cabinets. Expected service life spans four to seven years in standby applications. A two-year free-replacement warranty covers all non-UPS uses.
Highlights
- Reliable 12V power for UPS and backup systems
- 5Ah capacity delivers 90W of sustained energy
- Advanced AGM technology ensures maintenance-free operation
- Compact 5.94 x 2.56 x 3.66 dimensions fit standard enclosures
- Direct replacement for multiple OEM part numbers
Specifications
No published specifications for this item yet.
Questions about this item
What voltage and capacity does the 12V 7.5AH SLA battery deliver?
It supplies 12 volts at 7.5 amp-hours, rated for 90 watts, making it a direct replacement for 7 Ah and 8 Ah units.
What are the case dimensions and terminal style of the B-613 SLA1075?
The case measures 5.94 in long, 2.56 in wide, 3.66 in high and uses T1/T2 faston terminals.
How is the AGM battery installed in a UPS and what step is often missed?
Insert the battery, connect the red lead to the positive T1/T2 tab and the black lead to the negative tab, then secure the hold-down bracket — skipping the bracket lets the cell shift and break the connection.
Also in this aisle
People compared these