BatteryJack inc.
BatteryJack inc. 12V 12Ah F2 Sealed Lead Acid Deep-Cycle Rechargeable Battery
A 12V 12Ah sealed lead-acid battery with F2 terminals for UPS, alarm and emergency backup systems
- Reliable deep-cycle power for UPS and backup systems
- Advanced AGM technology enables maintenance-free operation
- Expected service life of 4 to 7 years
- Compact 151 × 98 × 101 mm footprint fits standard enclosures
- 100 % OEM replacement compatibility ensures direct fit
Ideal for UPS and alarm systems
This 12 V 12 Ah sealed lead-acid battery uses AGM technology to provide maintenance-free deep-cycle power. It is designed as a direct OEM replacement for uninterruptible power supplies, emergency lighting, security panels and similar backup applications.
F2 terminal limits high-current use
The F2 faston terminals suit the low-to-moderate discharge rates typical of UPS and alarm circuits. They are not intended for sustained high-current loads or frequent deep cycling beyond the rated capacity.
Rugged ABS case with compact footprint
The battery measures 151 mm long, 98 mm wide and 101 mm total height, weighing approximately 4.20 kg. Its sealed construction allows operation in any orientation without leakage, while the standard dimensions fit most industry-standard battery compartments.
Highlights
- Reliable deep-cycle power for UPS and backup systems
- Advanced AGM technology enables maintenance-free operation
- Expected service life of 4 to 7 years
- Compact 151 × 98 × 101 mm footprint fits standard enclosures
- 100 % OEM replacement compatibility ensures direct fit
Specifications
No published specifications for this item yet.
Questions about this item
Should I choose the 12Ah version or a different capacity for my UPS?
Select the 12Ah model only if your UPS or backup device specifies a 12V 12Ah battery; the 151mm length, 98mm width and 101mm total height must also match the compartment.
What does the 12Ah rating mean once the battery is installed in a UPS?
The 12Ah rating indicates the energy the battery can deliver over a 20-hour discharge; actual runtime depends on the UPS load, so a heavier load will give less run time than the rated capacity suggests.
What interface does the F2 terminal use and what does it limit?
The F2 terminal is a standard faston tab that connects by push-on; it limits the maximum current to what the tab and wiring can safely carry, so ensure your device's connector matches the F2 size.