Baldwin Filters
Baldwin Filters PT23085-MPG Hydraulic Filter Element 12 micron 92 gpm 3.06 in OD 1.5 in ID For Argo
A 12-micron hydraulic filter element rated for 92 gpm with a 3.06 in outside diameter and 1.5 in inside diameter, designed for Argo applications
- 12-micron filtration protects hydraulic components
- 92 gpm flow capacity supports high-demand systems
- 06 in outside diameter fits Argo housings
- 5 in inside diameter ensures secure cartridge seating
- Included O-ring provides reliable seal out of the box
Baldwin PT23085-MPG Hydraulic Filter Element
The Baldwin Filters PT23085-MPG is a cartridge-type hydraulic filter element rated at 12 micron with a 92 gpm flow capacity. It is designed for Argo hydraulic systems requiring 3.06 in outside diameter and 1.5 in inside diameter dimensions. Maintenance teams use it to protect pumps and valves from particle contamination.
Clean fluid reduces heat and pressure drop
A 12 micron rating captures fine debris that would otherwise increase fluid friction and raise operating temperatures. Consistent flow at 92 gpm helps the system maintain stable pressure without forcing the pump to work harder. Clean fluid also lowers the risk of cavitation noise in high-demand circuits.
Included O-ring simplifies installation
The supplied O-ring provides a positive seal between the element and the housing, preventing bypass leakage. No separate seal kit is required, which shortens service time during scheduled change-outs. The cartridge design allows direct replacement without special tools.
Highlights
- 12-micron filtration protects hydraulic components
- 92 gpm flow capacity supports high-demand systems
- 06 in outside diameter fits Argo housings
- 5 in inside diameter ensures secure cartridge seating
- Included O-ring provides reliable seal out of the box
Specifications
| Brand | BALDWIN FILTERS |
|---|
Questions about this item
How is the PT23085-MPG cartridge installed and which step is commonly missed?
Slide the cartridge over the 1.5 in centre post, seat the included O-ring in its groove, then torque the housing bowl to spec; the step often missed is lubricating the O-ring before assembly.
What replacement interval or maintenance does the 12 micron element require?
Replace the element when the system’s differential-pressure gauge reaches the manufacturer’s change-out threshold; no cleaning or re-use is possible for this 12 micron cartridge.
At what flow rate does the 92 gpm rating become the limiting factor during sustained operation?
Continuous flow above 92 gpm will exceed the element’s rated capacity and cause premature pressure rise across the 12 micron media.