Baldor Electric
Baldor Electric VL3509A 1 HP 3450 RPM 115/230V 56C TEFC Blower
Single-phase capacitor-start motor delivers 1 HP at 3450 RPM with dual-voltage 115/230V operation and TEFC enclosure
- MaterialHAWA
- 1 HP motor delivers 3450 RPM for high-speed airflow
- Dual-voltage 115/230V AC suits flexible wiring
- TEFC enclosure protects internals in dusty environments
- 56C face mount with keyed shaft simplifies installation
- Auto thermal protection and 1.25 service factor support continuous duty
Motor Purpose and Fit
The Baldor Electric VL3509A is a 1 HP single-phase capacitor-start motor built for continuous-duty service in industrial and commercial blower applications. Its 56C face-mount frame and keyed shaft suit direct-coupled equipment where a compact, footless mounting pattern is required. The totally enclosed fan-cooled enclosure protects windings from dust and moisture in dirty environments.
Capacity and Headroom
Rated at 3450 RPM with a 1.25 service factor, the motor delivers 12.0 amps at 115 V or 6.0 amps at 230 V while staying within Class B insulation limits at 40 °C ambient. It is not usable at 200 V or 208 V, so voltage selection must match the 115/230 V nameplate exactly. Auto thermal protection resets automatically after an overload cools.
Interface and Practical Limits
The unit operates on 60 Hz mains only and rotates in either clockwise or counter-clockwise direction as wired. Single-speed operation means no variable-speed control is possible without external equipment. Buyers needing multi-speed operation, lower-voltage supply, or a different frame size should select another model.
Highlights
- 1 HP motor delivers 3450 RPM for high-speed airflow
- Dual-voltage 115/230V AC suits flexible wiring
- TEFC enclosure protects internals in dusty environments
- 56C face mount with keyed shaft simplifies installation
- Auto thermal protection and 1.25 service factor support continuous duty
Specifications
| Brand | BALDOR ELECTRIC |
|---|---|
| Material | HAWA |
Questions about this item
Will the 56C face mount and keyed shaft line up with my existing 56-frame coupling and pulley?
The motor uses a standard 56C face mount with a keyed shaft, so it bolts directly to 56-frame couplings and pulleys without adapters.
How can I confirm the motor is running at the rated 3450 RPM and 12.0 / 6.0 full-load amps after wiring it for 115 or 230 V?
Measure shaft speed with a tachometer to verify 3450 RPM and clamp an ammeter on the supply leads to confirm 12.0 A at 115 V or 6.0 A at 230 V under load.
Does the box include a capacitor, mounting bolts or a wiring diagram, or must I source them separately?
The motor ships as a complete unit with internal capacitor-start components; mounting bolts and a wiring diagram are not included and must be sourced separately.