Atp
Atp PU14AG polyurethane drain trap 1/4 in OD 100 ft green
Polyurethane drain tubing with a 1/4 in outside diameter, 100 ft length and 180 psi maximum pressure rating
- TypeDrain Components
- ColorGreen
- 100 ft continuous length reduces joints
- 180 psi working pressure handles demanding systems
- Polyurethane construction resists abrasion and kinking
- 68 °F to 140 °F range suits extreme environments
- 28 in Hg vacuum rating prevents collapse under suction
Polyurethane tubing for fluid lines
This green polyurethane tube has a 1/4 inch outside diameter and a 5/32 inch inside diameter with a 3/64 inch wall thickness. It is supplied in a 100 foot coil and rated for 180 psi maximum pressure and 28 in Hg vacuum. The material carries a Shore A 98 hardness and operates from -68 to 140 degrees F.
Suited for pneumatic and low-pressure liquid
Installers who need flexible, abrasion-resistant tubing for air, water or inert gas lines will find this specification matches standard push-to-connect fittings. Systems that require higher temperature resistance, larger bore sizes or chemically incompatible fluid transfer should look at alternative materials.
1/4 inch outside diameter with 180 psi rating
The combination of 1/4 inch OD and 180 psi working pressure determines fitting compatibility and system safety margins. Verify that your connectors and operating conditions align with these dimensions before purchase.
Highlights
- 100 ft continuous length reduces joints
- 180 psi working pressure handles demanding systems
- Polyurethane construction resists abrasion and kinking
- 68 °F to 140 °F range suits extreme environments
- 28 in Hg vacuum rating prevents collapse under suction
Specifications
| Type | Drain Components |
|---|---|
| Color | Green |
| Brand | ATP |
| Model | PU14AG |
Questions about this item
Which length should I choose for a typical workshop run?
The tubing comes in a 100 ft coil so you can cut the exact length you need for each drain line.
What does the 180 psi burst rating mean when the line is pressurised?
It indicates the tube can withstand a momentary surge up to 180 psi before rupturing; design your system with a safety factor below that value.
How does the 1/4 in outside diameter affect flow capacity?
The 1/4 in OD with a 5/32 in bore sets the maximum flow area; pressure drop will increase with length and fluid viscosity.