Ashcroft
Ashcroft T27M0242EWVAC/30#GXCY Compound Transducer measurement tool
Electronic pressure transmitter measures vacuum to 30 psi with 4-20 mA output and ±0.25 % accuracy
- TypeElectronic
- Compound range covers vacuum to 30 psi for versatile monitoring
- 4–20 mA loop output enables long-distance signal transmission
- ±0.25 % full-scale accuracy delivers reliable readings
- NEMA 4X and IP66 ratings protect against harsh environments
- Operates from -40 to 257 °F for extreme-temperature applications
Pressure Transmitter Vacuum to 30 psi
The Ashcroft T2 series transmitter measures from -15 psi up to 30 psi and converts the reading into a 4 to 20 mA DC loop signal. It operates on a 9 to 36 V DC supply and connects through a 4-pin M12 connector with a 1/4 in male NPT process fitting.
Suits industrial pressure monitoring
This unit is built for process and automation engineers who need a two-wire loop-powered device with a NEMA 4X and IP66 rated nylon housing. It is not intended for applications that require a local display, a three- or four-wire voltage output, or a different process connection thread.
Deciding specification: +/- 0.25 % FS accuracy
The stated accuracy of ±0.25 % of full scale determines whether the transmitter meets the control-loop tolerance for a given installation. Verify that this precision satisfies the system error budget before specifying the part.
Highlights
- Compound range covers vacuum to 30 psi for versatile monitoring
- 4–20 mA loop output enables long-distance signal transmission
- ±0.25 % full-scale accuracy delivers reliable readings
- NEMA 4X and IP66 ratings protect against harsh environments
- Operates from -40 to 257 °F for extreme-temperature applications
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
Will the 4-pin M12 connector on this transducer mate with my existing 2-wire 4-20mA loop wiring?
Yes. The unit uses a 4-pin M12 connector but operates as a 2-wire loop-powered device on a 9-36V DC supply, so your existing 4-20mA wiring connects to the two active pins.
How do I verify the ±0.25% full-scale accuracy after installation?
Apply a calibrated pressure source at 0 psi and 30 psi, then confirm the output reads 4mA and 20mA respectively within the stated tolerance.
Does the box include the mating M12 cable or a 1/4 NPT seal, or must I order them separately?
The transducer ships with the 1/4 NPT male process connection installed; a mating M12 cable and any required thread sealant are not included and must be purchased separately.