We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Ashcroft

Ashcroft G2 Pressure Transducer -15 to 30 psi 4-20mA IP67 NEMA 4X

SKU CH-T2BY-7MB86

Measures -15 to 30 psi with 4-20mA output and ±0.50% accuracy in IP67 NEMA 4X housing

  • TypeElectronic
  • Wide vacuum-to-pressure range covers -15 to 30 psi
  • Rugged IP67 and NEMA 4X housing resists water and dust
  • 4-20 mA two-wire loop output simplifies integration
  • Operates reliably from -40 °F to 257 °F
  • ±0.5 % full-scale accuracy ensures precise readings

Industrial Pressure Transducer

The Ashcroft G2 pressure transducer measures vacuum to positive pressure from -15 to 30 psi with a 4 to 20mA DC output. It operates on 9 to 36V DC supply voltage through a two-wire loop-powered connection. The 1/4 inch male NPT process connection suits standard industrial piping.

Sustained Environmental Performance

Accuracy holds at +/- .50 percent full scale across the full operating range of -40 to 257 degrees Fahrenheit. The nylon housing meets NEMA 4X and IP67 ratings for ingress protection against dust and water immersion. Cable and wire leads provide the electrical interface for permanent installation.

Critical Selection Parameter

The pressure range of -15 to 30 psi determines whether this transducer matches the application vacuum and pressure requirements. Buyers who need a wider span or a different output protocol cannot use this model. Verify the process connection size and supply voltage before specifying.

Highlights

  • Wide vacuum-to-pressure range covers -15 to 30 psi
  • Rugged IP67 and NEMA 4X housing resists water and dust
  • 4-20 mA two-wire loop output simplifies integration
  • Operates reliably from -40 °F to 257 °F
  • ±0.5 % full-scale accuracy ensures precise readings

Specifications

BrandASHCROFT
TypeElectronic

Questions about this item

How much power does the 4 to 20mA output draw when the transducer runs continuously on a 24 V DC supply?

The transducer operates on 9 to 36 V DC and uses a 2-wire loop-powered 4 to 20 mA signal, so current draw stays within the 4 to 20 mA range regardless of supply voltage.

What process connection and wiring must the installer provide for the male 1/4 in NPT fitting and 2-wire cable leads?

The unit has a male 1/4 in NPT process connection and 2-wire cable leads; the installer supplies a matching female NPT port and a 9 to 36 V DC loop supply.

Will the IP67 and NEMA 4X nylon housing survive the same -40 to 257 °F range as my existing stainless steel sensors?

The nylon housing is rated IP67 and NEMA 4X with an operating range of -40 to 257 °F, matching the temperature limits of many stainless steel sensors.

Also in this aisle

People compared these