Ashcroft
Ashcroft G17M0242F2200# pressure transducer 0-200 psi
Measures 0 to 200 psi with 4 to 20 mA output, +/-0.50% full-scale accuracy, 1/4 NPT male connection, IP67 and NEMA 4X ratings, operating from -40 to 257 °F on 9 to 36 V DC
- TypeElectronic
- 0 to 200 psi range covers broad industrial pressure needs
- ±0.50 % full-scale accuracy delivers reliable measurement data
- 4–20 mA two-wire loop simplifies wiring and power supply
- NEMA 4X and IP67 ratings protect against dust and water ingress
- 40 to 257 °F operating span suits extreme temperature environments
Range and Output
The Ashcroft G17M0242F2200# pressure transducer measures gauge pressure from 0 to 200 psi and delivers a 4 to 20mA DC signal. It operates on a 9 to 36V DC supply through a two-wire loop. The housing carries NEMA 4X and IP67 ratings for harsh environments.
Suitability and Limits
This transmitter suits engineers who need a rugged, loop-powered sensor with +/- 0.50 percent full-scale accuracy across a -40 to 257 degrees F range. It is not for applications that require a voltage output, a different pressure span, or a flush-diaphragm process connection. Buyers needing a digital protocol or a sanitary fitting should look elsewhere.
Installation Checks
Verify that the 1/4 inch male NPT thread matches your port and that the cable leads reach your termination point. Confirm the control system accepts a 4 to 20mA current loop and can supply 9 to 36V DC. Ensure the nylon housing and wetted materials are compatible with your process media.
Highlights
- 0 to 200 psi range covers broad industrial pressure needs
- ±0.50 % full-scale accuracy delivers reliable measurement data
- 4–20 mA two-wire loop simplifies wiring and power supply
- NEMA 4X and IP67 ratings protect against dust and water ingress
- 40 to 257 °F operating span suits extreme temperature environments
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Electronic |
Questions about this item
What power supply must I already have to run this transducer?
A DC source between 9 V and 36 V capable of supplying the 4 to 20 mA loop current.
Can I keep my existing 1/4 inch NPT fittings when installing this unit?
Yes, the process connection is a male 1/4 inch NPT thread that matches those fittings.
How do I verify the output is correct after wiring it up?
Apply a known 200 psi reference pressure and confirm the output reads 20 mA within the stated accuracy.