Ashcroft
Ashcroft 30EI60R Bi-Metallic Dial Thermometer 6 in Stem 0 to 250 Degrees F
Bi-metallic dial thermometer with a 6-inch stem measuring 0 to 250 degrees Fahrenheit and includes a NIST-traceable certificate
- TypeEnvironmental & Mechanical
- Accurate readings from 0 °F to 250 °F for wide-range monitoring
- Dual-scale display in °F and °C simplifies cross-unit checks
- Six-inch stem reaches deep into tanks or ducts
- Stainless-steel housing resists corrosion in harsh environments
- Glass lens protects dial from impact and chemical splatter
Industrial Temperature Monitoring
The Ashcroft 30EI60R bi-metallic dial thermometer measures temperatures from 0 to 250 degrees Fahrenheit with a six-inch stem. It suits plant engineers and maintenance technicians who need direct local readings on pipes or vessels. The stainless-steel housing and glass lens withstand harsh process environments. Buyers who require digital logging or remote transmission should choose a different instrument type.
Thermals Noise And Power
The mechanical bi-metallic element operates without external power so there is no electrical draw and no fan noise. Ambient temperature does not affect the reading because the stem inserts directly into the medium being measured. The glass lens resists fogging in humid conditions. Installers who need illuminated displays or alarm outputs will not find those features here.
Dual Scale Range Decision
The dial shows both Fahrenheit and Celsius scales covering 0 to 250 degrees Fahrenheit and minus 20 to 120 degrees Celsius. This single range determines whether the thermometer matches your process limits. The half-inch NPT back connection fits standard thermowells. Applications outside this temperature window require a different model.
Highlights
- Accurate readings from 0 °F to 250 °F for wide-range monitoring
- Dual-scale display in °F and °C simplifies cross-unit checks
- Six-inch stem reaches deep into tanks or ducts
- Stainless-steel housing resists corrosion in harsh environments
- Glass lens protects dial from impact and chemical splatter
Specifications
| Brand | ASHCROFT |
|---|---|
| Type | Environmental & Mechanical |
Questions about this item
How is the 1/2 in NPT back connection installed, and what step is often missed?
Thread the 1/2 in NPT back fitting into the matching port using pipe sealant; the step often missed is tightening to the correct torque so the 3 in dial sits square without stress on the 6 in stem.
What maintenance or replacement will the bi-metallic element need over time?
The bi-metallic coil requires periodic calibration checks against a known reference; if drift exceeds the 0 to 250 Degrees F range tolerance, the entire thermometer must be replaced.
What limit appears first when the thermometer is left at the top of its scale continuously?
Sustained exposure near 250 Degrees F can accelerate fatigue in the bi-metallic coil, causing permanent calibration shift before the stainless steel housing or glass lens shows any degradation.