Apollo 77W10501A Ball Valve 1 in Press 300 psi
A full-port brass ball valve with press connection for 1 in pipe, rated 300 psi CWP and 250 °F maximum temperature
- Full-port design ensures unrestricted flow
- Press connection enables fast, secure installation
- Brass body resists corrosion for long service
- Blowout-proof stem prevents stem ejection under pressure
- Rated 300 psi CWP for demanding applications
Brass Inline Ball Valve
The Apollo 77W10501A is a 1 in press‑connection ball valve with a brass body and chrome‑plated brass ball. It suits residential and light‑commercial plumbing, irrigation and hydronic systems that require a full‑port, inline shut‑off valve rated for 300 psi CWP. Installers who need a blowout‑proof stem and lever handle with vinyl grip will find it ready for service from 0 to 250 °F.
Replaces Threaded Or Soldered Valves
The press connection eliminates threading or soldering on 1 in copper or stainless tubing, cutting install time and avoiding open flame. The step up is worth it when a project demands a secure, leak‑free joint without the labour of traditional fittings, especially on retrofits where pipe rotation is limited. The 15 psi WSP rating covers low‑pressure steam applications.
Fits Press‑Tool Workflows
The valve connects directly to 1 in press‑compatible tubing using a standard press tool, so no separate adapters, flux or solder are required. Its two‑piece brass body with Buna‑N seal and RPTFE seats handles water, oil and air lines within the stated temperature and pressure range. The lever handle provides clear on/off indication and the blowout‑proof stem adds safety during maintenance.
Highlights
- Full-port design ensures unrestricted flow
- Press connection enables fast, secure installation
- Brass body resists corrosion for long service
- Blowout-proof stem prevents stem ejection under pressure
- Rated 300 psi CWP for demanding applications
Specifications
| Brand | APOLLO |
|---|
Questions about this item
What pipe size and connection type does the Apollo 77W10501A require for press fitting?
The valve is built for a 1 in pipe size and uses a press connection, so the tubing must be 1 in and compatible with press tooling for a secure joint.
How is the valve installed, and which step is commonly missed?
After pressing the 1 in connections onto the tubing, the lever handle must be fully cycled open and closed to seat the RPTFE seats against the chrome plated brass ball; skipping this cycle can leave the seats unseated and cause leaks.
Which components will need replacement over time on this valve?
The RPTFE seats and Buna-N body seal are the wear items; they should be inspected periodically and replaced if the valve shows seepage or becomes hard to operate within the 0 to 250 degrees F range.