Amprobe TMD-10 Dual-Input Thermocouple Thermometer
Measures temperature via dual Type J and K inputs from -328°F to 2498°F with ±(0.05% + 1.4°F) accuracy and includes two K-type probes
- Dual thermocouple inputs enable simultaneous temperature readings
- Type K range spans -328 °F to 2498 °F for extreme environments
- Type J range covers -328 °F to 1922 °F for industrial processes
- Accuracy within ±(0.05 % + 1.4 °F) ensures reliable measurements
- Includes two K-type probes, instructions and carrying case for immediate use
Dual-Input Thermocouple Thermometer
The Amprobe TMD-10 accepts two thermocouple inputs simultaneously. It supports Type K and Type J sensors for industrial and HVAC temperature measurement. The kit includes two K-type probes, a carrying case and instructions.
Technicians Needing Differential Readings
Professionals monitoring supply and return temperatures or comparing two points benefit from the dual channels. Users requiring only single-point measurement or different thermocouple types should consider other instruments.
Type K Range to 2498 Degrees F
Type K sensors cover -328 to 2498 degrees Fahrenheit on this meter. Type J covers -328 to 1922 degrees Fahrenheit. Accuracy is specified as plus or minus 0.05 percent plus 1.4 degrees Fahrenheit.
Highlights
- Dual thermocouple inputs enable simultaneous temperature readings
- Type K range spans -328 °F to 2498 °F for extreme environments
- Type J range covers -328 °F to 1922 °F for industrial processes
- Accuracy within ±(0.05 % + 1.4 °F) ensures reliable measurements
- Includes two K-type probes, instructions and carrying case for immediate use
Specifications
| Brand | Amprobe |
|---|
Questions about this item
What thermocouple probe types does the TMD-10 accept?
The meter has dual inputs for Type K and Type J thermocouples. Two K-type probes are included in the box.
How do I set up the meter for the first measurement?
Insert the probe plugs into the two input jacks, select the matching thermocouple type on the display, then power on. People often forget to change the type setting from the default.
When should I replace the included K-type probes?
Replace probes if the stainless sheath shows corrosion, the tip is bent, or readings drift beyond the stated accuracy of ±(0.05% + 1.4 °F).