We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

3M

3M MNG14-6R/SX 16-14 AWG Nylon Ring Terminal #6 Stud Blue PK100

SKU CH-65GD-X6NJ6

Nylon-insulated ring terminals accept 16-14 AWG wire onto a #6 stud, 100 per pack

  • Length2.000
  • MaterialCopper
  • TypeBuilding Wire
  • Blue insulation identifies 16-14 AWG wire range
  • Brazed seam resists separation during crimp connection
  • Nylon insulation rated to 221 °F for thermal durability
  • UL listed and CSA certified for 600 V applications
  • Pack of 100 terminals supports volume wiring jobs

3M MNG14-6R/SX Ring Terminals

These 3M ring terminals accept 16 to 14 AWG wire and fit a #6 stud. The blue nylon insulation is rated for 600 V and 221 °F. Each pack contains 100 crimp-type connectors suited for automotive or general electrical work.

Thermals and Electrical Ratings

The copper barrel with brazed seam handles up to 600 V and a maximum temperature of 221 °F. Nylon insulation resists heat and abrasion during normal operation. No active cooling or power draw is involved with these passive components.

Build and Mounting Details

Overall length measures 0.81 in with a tongue width of 0.25 in. The crimp connection method requires an appropriate tool for secure termination. Blue colour coding aids quick identification in dense wiring looms.

Highlights

  • Blue insulation identifies 16-14 AWG wire range
  • Brazed seam resists separation during crimp connection
  • Nylon insulation rated to 221 °F for thermal durability
  • UL listed and CSA certified for 600 V applications
  • Pack of 100 terminals supports volume wiring jobs

Specifications

Brand3M
Length2.000
MaterialCopper
TypeBuilding Wire

Questions about this item

How do I crimp the 16-14 AWG ring terminal and which step is often missed?

Strip the wire to the correct length, insert fully into the barrel, and crimp with a ratchet tool matched to 16-14 AWG; the step most often missed is verifying the crimp with a go/no-go gauge before heat-shrinking.

What maintenance or replacement will the nylon-insulated #6 stud terminals need over time?

Inspect each connection for cracked blue nylon insulation, corrosion on the copper barrel, or loose crimps after thermal cycling; replace any terminal showing discoloration or mechanical damage.

At what temperature limit does the 221 °F rating become the first constraint under sustained load?

The 221 °F maximum operating temperature is the first limit reached; continuous current that raises the terminal above this value degrades the nylon insulation and weakens the crimp joint.